塔式脫氧與高濃稀釋系統

24

產品名稱: TYXS系列(lie)塔式脫氧與(yu)高濃(nong)稀(xi)釋

發布日(ri)期(qi): 2017-11-14

點擊數: 2613

詢價: 點擊產品詢價

二(er)維(wei)碼:

產品詳情

產品說明:
      塔式脫氧水制備系統是在國外技術基礎上加以消化吸收而開發的一種產品。產品脫氧性能精度高、穩定性好、可靠性強,設備廣泛應用于各種需要高純度脫氧水的應用場合。
塔高約6米,直接將釀造水進去脫氧塔進行脫氧,采用二氧化碳置換,在完成脫氧的同事脫氧水也達到了部分碳酸化目的。
       脫氧水在經過薄板冷卻后與清酒混合達到客戶需要的成品酒。薄板冷卻溫度采用自動控制系統,為了讓西施水中二氧化碳含量達到稀釋水的工藝指標,系統配備了二氧化碳飽沖器。確保二氧化碳在水中的穩定性,清酒和脫氧水混合通過模塊控制脫氧水流量,確保混合精度。系統通過微機自動完成。
Tower deaerated water preparation system is based onforeign technology to the digestion, absorption, and the development of a product. Product solid performance accuracy, good stability, high reliability, equipment widely used in various applications require high purity deaerated water. About 6 meters high tower, the brewing water directly 

into deaeration tower with DNA, adopt co2 permutation, colleagues in complete deoxidizing deaerated water also reached the part of the real purpose. Deaerated water after cooling plate product wine mixed with wine to customers need. Sheet cooling temperature   adopts the automatic control system, to allow xi shi content of co2 in water to dilute water technology index, system equipped with co2 full punch. To ensure the stability of the carbon dioxide in the water, clear wine and deaeration watermixed deoxidization water flow through module control, ensure that mixing  precision.

工藝流程:
        無菌水通過自動流量閥進入板式換熱器,在進入脫氣塔之前,無菌水經過板式換熱器的熱回收預加熱至72度,用戶所要求的進入無菌水的流量在進去板式換熱器前通過控制柜并且自動控制,水在脫氣塔的頂部進行分流,按照與置換氣體逆向流動的要求從上往下流,置換氣體從氣塔底部通過泵送至板式換熱器的冷卻并達到所
要求的溫度,為了保證泵不至于吸空,在脫氣塔的底部設有液位控制以保持脫氣塔底部具有一定的液位
最終的脫氧水的碳酸化是通過二氧化碳噴射進冷卻段脫氧水進口實現的,最終的成品脫氧水通過換向閥被泵送到脫氧水儲罐。

Technological process:
Sterile water through automatic flow valve into the plate heat exchanger, before entering the degassing tower, sterile water through a plate
The heat recovery heat exchanger pre heated to 72 degrees, required by the user into the sterile water flow on the plate
Automatically by the control cabinet and control before heat exchanger, water at the top of the degassing tower, to exchange gases
On the requirements of reverse flow from flowing downwards, displacement gas from gas bottom through the pump to the cooling of plate heat exchanger and reach
Require temperature, in order to ensure the pump not empty absorption, at the bottom of the degassing tower is equipped with liquid level control to maintain the degassing the bottom has a certain level
Carbonate by carbon dioxide is a final deaerated water injection into the cooling period of deaerated water imports, the final finished product deaerated water pump to the deaeration water storage tank by reversing valve.